Daikin FTXR42EV1B9 Especificaciones Pagina 83

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 167
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 82
SiBE04-624_B Convenient Service Check Function
Service Diagnosis 73
1. Convenient Service Check Function
1.1 Indoor Unit
Multi-colored
Indicator Lamp
The multi-colored indicator lamp blinks when any of the following errors is detected.
1. When a protection device of the indoor or outdoor unit is activated, or when the thermistor
malfunctions.
2. When a signal transmission error occurs between the indoor and outdoor units.
In either case, conduct the diagnostic procedure described in the following pages.
Service Monitor The indoor unit has one green LED (LED A) on the control PCB. When the microcomputer
works in order, the LED A blinks.
Remote
Controller
With the wireless remote controller, error codes can be confirmed.
1. Hold the timer cancel button down for 5 seconds, with the remote controller set toward the
indoor unit.
2. The display on the remote controller shows an error code with a long beep.
<Note>
To cancel the indication of error code, hold the timer cancel button down for 5 seconds.
When the remote controller is left untouched for 60 seconds, it also returns to the normal mode.
1.2 Outdoor Unit
The outdoor unit has 2 green LEDs (LED A, LED 5) on the PCB. When the microcomputer
works in order, the LEDs blink.
(R5990)
Multi-colored indicator lamp
E5
(R18113)
Timer cancel
button
(R5074)