130 Service Diagnosis
2.38 Fan Motor System Abnormality / Fan Lock
Error Code
P9
Method of Error
Detection
During humidifying fan motor running, fan motor system abnormality is identified based on the
fan rotation speed (rpm) detected by Hall IC.
Error Decision
Conditions
<Humidifying fan>
When the fan rotation speed does not reach 100 rpm within 7 seconds after the fan motor starts.
Supposed
Causes
<Humidifying fan>
Defective humidifying fan motor
Breakage of relay harness or loose connector
Detection fault of fan rotation speed due to defective outdoor unit PCB
Troubleshooting
Check No.16
Refer to P.140
(R18134)
Is the
connector for the
humidifying fan motor [S72]
connected?
Caution
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
YES
YES
YES
YES
<Others>
<Humidifying fan>
<Humidifying fan>
Rotate the fan by hand after
removing it.
Check No.16
Check for the rotation pulse
input of outdoor unit PCB.
NO
NO
NO
NO
Does the fan rotate?
Stop operation.
Is the fuse for power
supply of fan (FU2)
blown?
Does the fan rotate
smoothly?
After reassembling, start operation.
Start humidifying operation.
Reconnect the connector
properly.
Replace the humidifying fan
assembly.
Replace the outdoor fan
motor, humidifying fan
motor, outdoor unit PCB.
Replace the outdoor unit
PCB.
Completed.