SiBE04-624_B Main Functions
Function and Control 33
1.9 MOISTURIZING Operation
Operation
Effective mode for MOISTURE COOLING operation
•COOLING
• DRY COOLING
Effective mode for MOISTURE HEATING operation
• HEATING
• HUMID HEATING
Features
MOISTURIZING operation has following 3 features.
• Relatively high humidity setting
• COMFORT AIRFLOW operation
• Emission of vitamins and hyaluronic acid
MOISTURIZING operation is not for beauty and beautiful skin treatment, nor prevention of
skin roughness.
Details of operation
MOISTURIZING operation
(R13878)
Time
MOISTURE COOLING 65%
DRY COOLING 50~60%
Room humidity
Rotation speed of indoor unit fan
<Humidity in MOISTURE COOLING operation>
Raise humidity to 65%
Humidity%
(R18351)
• MOISTURE COOLING operation keeps the humidity at 65%.
• Unlike ordinary DRY COOLING, it prevents the room from drying.
Time
MOISTURE HEATING 60%
HUMID HEATING 45~55%
Room humidity
Rotation speed of indoor unit fan
<Humidity in MOISTURE HEATING operation>
Raise humidity to 60%
Humidity%
(R18352)
• MOISTURE HEATING operation keeps the humidity at 60%.
• Air is moisturized more than in ordinary HUMID HEATING.