SiBE04-624_B Main Functions
Function and Control 19
1.3.6 COOLING BREEZE Operation
Operation
Effective mode for COOLING BREEZE operation
•COOLING
“SARARA” DRYING
DRY COOLING
FLASH STREAMER AIR PURIFYING
Note On AUTO operation, when the actual operation mode is HEATING, COOLING BREEZE
operation does not work. (Indication on the remote controller remains.)
Flap motion
As shown in the graph below, the standard position is the upper limit of the swing so that you
do not feel draft.
Depending on the room temperature and the thermostat ON/OFF state, swing interval
varies.
(The lower the temperature, the longer the swing interval, thereby comfort is maintained.)
Left and right flaps move according to the setting of the remote controller.
Airflow rate
Airflow rate is controlled automatically.
Features
1/f fluctuation rhythm switches airflow direction.
By fluctuating airflow direction you can feel cool even the room temperature is set rather
high.
By 1/f fluctuation rhythm, upper and lower flaps move up and down unlike the conventional
up and down swing, and this movement brings you a comfortable air like a breeze in nature.
(R13855)
The indication changes every time “ ” is pressed.
Indication disappears
COOLING
BREEZE
Operation
Displays COMFORT
AIRFLOW operation
Displays COOLING
BREEZE operation
Swing
Time
Example
Lower limit of swing
(R18140)
The flaps swing from draftless position to the lower limit of
swing by 1/f fluctuation rhythm.
Upper limit of swing
= Draftless position