Main Functions SiBE04-624_B
44 Function and Control
Switching air supply / exhausting
This function was realized by developing damper inside the humidifier unit.
Conditions for operation
1. Accumulated operation time: 21,600 minutes (approx.15 days)
2. Accumulated “SARARA” DRYING and COOLING operation time: 5,400 minutes (approx.15
days × 6 hours)
This function starts when both conditions are met.
Note:
This is not the function for eliminating dust or mold attached inside the air conditioner.
During operation, smells may occur.
This function sometimes does not begin when outdoor temperature or indoor humidity is
extremely high.
Depending on the temperature conditions, moisture exhaustion function is not carried out.
1. Drained water discharge
Drained water in the drain pan is discharged.
2. Inside drying operation
After the drained water discharged, the moisture which
are left on the drain pan or the indoor heat exchanger
are dried by evaporation.
3. Moisture exhaustion
Moisture is exhausted to outdoors through the humidification hose.
Air supply position Exhausting position
To Outdoor
To Indoor
From Indoor
From Outdoor
(R18354)