
SiBE05-722_A Indoor Unit
Removal Procedure 119
1.4 Removal of Signal Receiver Unit / Swing Motor
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step Procedure Points
1. Remove the signal
receiver unit.
1
Unfasten the 2 hooks
(right and left sides) to
remove the signal
receiver unit.
2
Remove the wire
harness of the signal
receiver unit from the
groove.
Note:
Rearrange the wire harness in
position as it was when
reassembling signal receiver
unit.
2. Remove the swing motor.
1
Remove the 2 screws
and remove the swing
motor.
Signal receiver unit
(R2995)
Swing motor
(R2998)
Comentarios a estos manuales