Functions SiBE05-722_A
2 List of Functions
1. Functions
Category Functions
FLKS25/35BAVMB
RKS25/35E2V1B
FLXS25/35BAVMB
RXS25/35E2V1B
Category Functions
FLKS25/35BAVMB
RKS25/35E2V1B
FLXS25/35BAVMB
RXS25/35E2V1B
Basic
Function
Inverter (with Inverter Power Control)
{{
Health &
Clean
Air-Purifying Filter
{{
Operation Limit for Cooling (°CDB)
–10
~46
–10
~46
Photocatalytic Deodorizing Filter
{{
Operation Limit for Heating (°CWB)
–15
~20
Air-Purifying Filter with Photocatalytic
Deodorizing Function
——
PAM Control
{{
Titanium Apatite Photocatalytic
Air-Purifying Filter
——
Standby Electricity Saving
Compressor Oval Scroll Compressor Air Filter (Prefilter)
{{
Swing Compressor
{{
Wipe-Clean Flat Panel
Rotary Compressor Washable Grille
Reluctance DC Motor
{{
MOLD PROOF Operation
Comfortable
Airflow
Power-Airflow Flap Good-Sleep Cooling Operation
Power-Airflow Dual Flaps
Timer WEEKLY TIMER Operation
24-Hour ON/OFF TIMER
{{
Power-Airflow Diffuser NIGHT SET Mode
{{
Wide-Angle Louvers Worry Free
“Reliability &
Durability”
Auto-Restart (after Power Failure)
{{
Vertical Auto-Swing (Up and Down)
{{
Self-Diagnosis (Digital, LED) Display
{{
Horizontal Auto-Swing (Right and Left) Wiring Error Check Function
3-D Airflow
Anti-Corrosion Treatment of Outdoor
Heat Exchanger
{{
Comfort
Control
Auto Fan Speed
{{
Indoor Unit Quiet Operation
{{
Flexibility
Multi-Split/Split Type Compatible Indoor
Unit
{{
NIGHT QUIET Mode (Automatic)
OUTDOOR UNIT QUIET Operation
(Manual)
{{
Flexible Voltage Correspondence
INTELLIGENT EYE Operation Chargeless
10
m
10
m
Quick Warming Function
(Preheating Operation)
{
Either Side Drain (Right or Left)
Hot-Start Function
{
Power Selection
Automatic Defrosting
{
Remote
Control
5-Rooms Centralized Controller (Option)
{{
Operation Automatic Operation
{
Remote Control Adaptor
(Normal Open Pulse Contact) (Option)
{{
Program Dry Operation
{{
Fan Only
{{
Remote Control Adaptor
(Normal Open Contact) (Option)
{{
Lifestyle
Convenience
New POWERFUL Operation
(Non-Inverter)
——
Inverter POWERFUL Operation
{{
DIII-NET Compatible (Adaptor) (Option)
{{
Priority-Room Setting Remote
Controller
Wireless
{{
COOL/HEAT Mode Lock Wired (Option)
HOME LEAVE Operation
{{
ECONO Operation
Indoor Unit ON/OFF Button
{{
Signal Receiving Sign
{{
R/C with Back Light
Temperature Display
Note:
{
: Holding Functions
: No Functions
: Lower limit can be extended to –15°C by cutting
jumper. (facility use only)