Troubleshooting SiBE05-722_A
92 Service Diagnosis
Troubleshooting RK(X)S25/35E2V1B models
Check No.06
Refer to P.105
Check No.07
Refer to P.106
Check No.09
Refer to P.107
Caution
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
WARNING
To cool the electrical components,
the outdoor fan starts when the
radiation fin temperature rises
above ˚C and stops when it
drops below ˚C.
(R10727)
YES
∗ Fin thermistor
NO
Slightly dirty
Malfunctioning
Too dirty
Functioning
NO
YES
NO
YES
Turn off the power and turn it on
again.
Check the radiation fin
temperature.
Check No. 07
Check the installation condition.
Radiation fin dirty?
Above ˚C?
Thermistor as
specified in its characteristic
chart?
Check No. 06
Check the thermistor resistance
value.
Check No. 09
Check the outdoor fan or
related.
Error again or outdoor
fan activated?
Replace the fin thermistor.
Replace the outdoor unit
PCB.
Replace the outdoor unit
PCB.
Replace the fan motor.
Correct the connectors and
the fan motor lead wire.
Clean up the radiation fin.
(°C) (°C) (°C)
RK(X)S25/35E2V1B 80 70 80
Comentarios a estos manuales