Specifications SiEN04-306D
34 Specifications
50Hz 240V
Note: MAX. interunit piping length: 30m
MAX. interunit height difference: 20m
Amount of additional charge for piping length exceeding 10m : 50g/m
The data are based on the conditions shown in the table below.
Model
Indoor Units FTXD80CV4
Outdoor Units
RXD80CV4
Cooling Heating
Capacity
Rated (Min.~Max.)
kW 8.0(0.9~8.5) 9.5 (0.9~10.2)
Btu/h 27,310 (3,070~29,000) 32,420 (3,070~34,820)
kcal/h 6,880 (770~7,310) 8,180 (770~8,780)
Moisture Removal L/h 4.8 —
Running Current (Rated) A 13.9 14.0
Power Consumption
Rated (Min.~Max.)
W 3,300 (450~3,950) 3,320 (450~3,490)
Power Factor % 98.9 98.8
COP W/W 2.42 2.86
Piping
Connections
Liquid mm φ 9.5
Gas mm φ15.9
Drain mm φ18.0
Heat Insulation Both Liquid and Gas Pipes
Indoor Unit FTXD80CV4
Front Panel Color White
Air Flow Rate
m
3
/min
(cfm)
H 20.9 (738) 20.8 (734)
M 18.1 (637) 18.3 (646)
L 15.2 (537) 15.8 (558)
SL 13.4 (473) 14.2 (502)
Fan
Type Cross Flow Fan
Motor Output W 43
Speed Steps 5 Steps, Silent and Auto
Air Direction Control Right, Left, Horizontal and Downward
Air Filter Removable / Washable / Mildew Proof
Running Current (Rated) A 0.30 0.27
Power Consumption (Rated) W 70 64
Power Factor % 98.2 98.8
Temperature Control Microcomputer Control
Dimensions (H×W×D) mm 290×1,050×238
Packaged Dimensions (H×W×D) mm 337×1,147×366
Weight kg 12
Gross Weight kg 17
Operation
Sound
H/M/L/SL dBA 49/45/40/37 47/43/38/35
Sound Power H dBA 65 63
Outdoor Unit RXD80CV4
Casing Color Ivory White
Compressor
Type Hermetically Sealed Swing Type
Model 2YC63ZXD
Motor Output W 1,900
Refrigerant
Oil
Model SUNISO 4GSD.I.
Charge L 0.75
Refrigerant
Model R22
Charge kg 1.80
Air Flow Rate m
3
/min (cfm)
H 51.5(1,818) 41.9(1,479)
L 41.5(1,465) 41.9(1,479)
Fan
Type Propeller
Motor Output W 53
Running Current (Rated) A 13.6 13.7
Power Consumption (Rated) W 3,230 3,250
Power Factor % 99.0 98.8
Starting Current A 11.3
Dimensions (H×W×D) mm 735×825×300
Packaged Dimensions (H×W×D) mm 784×960×390
Weight kg 57
Gross Weight kg 61
Operation
Sound
H/L dBA 52/49 52/49
Sound Power H dBA 66 66
Drawing No. 3D043427
Conversion Formula
kcal/h=kW×860
Btu/h=kW×3414
cfm=m
3
/min×35.3
Cooling Heating Piping Length
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB/24°CWB
Indoor ; 20°CDB
Outdoor ; 7°CDB/6°CWB
7.5m