Specifications SiEN04-306D
28 Specifications
50Hz 230V
Note:
MAX. interunit piping length: 30m
MIN. interunit piping length: 1.5m
MAX. interunit height difference: 20m
Amount of additional charge of refrigerant 20g/m for piping length exceeding 10m
The data are based on the conditions shown in the table below.
Model
Indoor Units FTYS50BVMB FTYS60BVMB
Outdoor Units
RYS50B(2)VMB RYS60B(2)VMB
Cooling Heating Cooling Heating
Capacity
Rated
kW 5.0 5.8 6.0 7.0
Btu/h 17,070 19,800 20,480 23,900
kcal/h 4,300 4,990 5,160 6,020
Moisture Removal L/h 2.9 3.9
Running Current (Rated) A 7.3 7.5 9.3 9.2
Power Consumption
Rated
W 1,660 1,700 2,120 2,090
Power Factor % 98.9 98.6 99.1 98.8
COP W/W 3.01 3.41 2.83 3.35
Piping
Connections
Liquid mm φ 6.4 φ 6.4
Gas mm φ12.7 φ12.7
Drain mm φ18.0 φ18.0
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Indoor Unit FTYS50BVMB FTYS60BVMB
Front Panel Color White White
Air Flow Rate
m
3
/min
(cfm)
H 11.5 (406) 12.2 (431) 16.4 (579) 17.5 (618)
M 9.8 (346) 10.5 (371) 13.9 (491) 15.2 (537)
L 8.3 (293) 8.8 (311) 11.6 (409) 12.8 (452)
Fan
Type Cross Flow Fan Cross Flow Fan
Motor Output W 40 43
Speed Steps 5 Steps and Auto 5 Steps and Auto
Air Direction Control Right, Left, Horizontal and Downward Right, Left, Horizontal and Downward
Air Filter Removable / Washable / Mildew Proof Removable / Washable / Mildew Proof
Running Current (Rated) A 0.18 0.18 0.18 0.18
Power Consumption (Rated) W 40 40 40 40
Power Factor % 96.6 96.6 96.6 96.6
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H×W×D) mm 290×795×230 290×1,050×230
Packaged Dimensions (H×W×D) mm 280×840×338 337×1,147×366
Weight kg 9 12
Gross Weight kg 13 17
Operation
Sound
H/L dBA 44/35 42/— 45/36 44/—
Sound Power H dBA 63 60 63 62
Outdoor Unit RYS50B(2)VMB RYS60B(2)VMB
Casing Color Ivory White Ivory White
Compressor
Type Hermetically Sealed Swing Type Hermetically Sealed Swing Type
Model 2YC32HXD 2YC32HXD
Motor Output W 1,500 1,500
Refrigerant
Oil
Model FVC50K FVC50K
Charge L 0.65 0.65
Refrigerant
Model R-410A R-410A
Charge kg 1.20 1.70
Air Flow Rate m
3
/min (cfm)
H 47.7(1,684) 44.1(1,557) 47.6(1,680) 45.5(1,606)
L 44.1(1,557) 44.1(1,557) 44.1(1,557) 45.5(1,606)
Fan
Type Propeller Propeller
Motor Output W 53 53
Running Current (Rated) A 7.12 7.32 9.12 9.02
Power Consumption (Rated) W 1,620 1,660 2,080 2,050
Power Factor % 98.9 98.6 99.2 98.8
Starting Current A 7.5 9.3
Dimensions (H×W×D) mm 735×825×300 735×825×300
Packaged Dimensions (H×W×D) mm 784×960×390 784×960×390
Weight kg 49 53
Gross Weight kg 53 57
Operation
Sound
H dBA 47 48 49 49
Sound Power H dBA 63 64 64 64
Drawing No. 3D040784A 3D040785
Conversion Formula
kcal/h=kW×860
Btu/h=kW×3414
cfm=m
3
/min×35.3
Cooling Heating Piping Length
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB/24°CWB
Indoor ; 20°CDB
Outdoor ; 7°CDB/6°CWB
7.5m