SiEN04-306D Specifications
Specifications 33
50Hz 240V
Note: MAX. interunit piping length: 30m
MAX. interunit height difference: 20m
Amount of additional charge for piping length exceeding 10m : 20g/m
The data are based on the conditions shown in the table below.
Model
Indoor Unit FTXD50BV4
Outdoor Unit
RXD50BV4
Cooling Heating
Capacity
Rated (Min.~Max.)
kW 4.8 (0.9~5.2) 6.0 (0.9~7.3)
Btu/h 16,390 (3,070~17,750) 20,480 (3,070~24,920)
kcal/h 4,130 (770~4,470) 5,160 (770~6,280)
Moisture Removal L/h 2.9 —
Running Current (Rated) A 7.3 8.2
Power Consumption
Rated (Min.~Max.)
W 1,740 (450~1,950) 1,950 (450~2,300)
Power Factor % 99.3 99.1
COP W/W 2.76 3.08
Piping
Connections
Liquid mm φ 6.4
Gas mm φ12.7
Drain mm φ18.0
Heat Insulation Both Liquid and Gas Pipes
Indoor Unit FTXD50BV4
Front Panel Color White
Air Flow Rate
m
3
/min
(cfm)
H 12.3 (433) 13.4 (474)
M 10.4 (366) 11.4 (402)
L 8.6 (303) 9.3 (329)
SL 7.6 (268) 8.2 (291)
Fan
Type Cross Flow Fan
Motor Output W 40
Speed Steps 5 Steps, Silent and Auto
Air Direction Control Right, Left, Horizontal and Downward
Air Filter Removable / Washable / Mildew Proof
Running Current (Rated) A 0.18 0.18
Power Consumption (Rated) W 40 40
Power Factor % 92.6 92.6
Temperature Control Microcomputer Control
Dimensions (H×W×D) mm 290×795×238
Packaged Dimensions (H×W×D) mm 280×840×338
Weight kg 9
Gross Weight kg 13
Operation
Sound
H/M/L/SL dBA 44/40/35/32 42/38/33/30
Sound Power H dBA 63 60
Outdoor Unit RXD50BV4
Casing Color Ivory White
Compressor
Type Hermetically Sealed Swing Type
Model 2YC32UXD
Motor Output W 1,500
Refrigerant
Oil
Model SE50P
Charge L 0.65
Refrigerant
Model R22
Charge kg 1.25
Air Flow Rate m
3
/min (cfm)
H 42.8(1,511) 40.7(1,437)
L 40.7(1,437) 40.7(1,437)
Fan
Type Propeller
Motor Output W 53
Running Current (Rated) A 7.12 8.02
Power Consumption (Rated) W 1,700 1,910
Power Factor % 99.5 99.2
Starting Current A 7.2
Dimensions (H×W×D) mm 735×825×300
Packaged Dimensions (H×W×D) mm 784×960×390
Weight kg 49
Gross Weight kg 54
Operation
Sound
H/L dBA 47/44 48/45
Sound Power H dBA 63 64
Drawing No. 3D040788
Conversion Formula
kcal/h=kW×860
Btu/h=kW×3414
cfm=m
3
/min×35.3
Cooling Heating Piping Length
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB/24°CWB
Indoor ; 20°CDB
Outdoor ; 7°CDB/6°CWB
7.5m