5. Operation method
Turn the power on to the product after connecting the Transmission Monitor according to “4.Connection
method to product". After five seconds, the product starts communication between indoor and outdoor units.
The Transmission Monitor automatically judges the communication method to display the received data on
LCD.
The user selects the sender of signal to be monitored with the use of IN/OUT changeover switch, (select
indoor unit to monitor the indoor temperature, or outdoor unit to monitor compressor operating frequency of
outdoor unit) and then select pages that display the required data using of Display changeover switch. Page
No. is displayed by xP on the upper right of LCD. The number of pages depends on the transmission
method applied (e.g.1 or 7). The LCD display examples are shown below.
Out-DrComp=OFF 1P
INV:MultiHTpump
OutDr=HEAT
ALARM =H8
ψ
INDOOR 0 COOL 1P
Capacity=1.8kW
TYPE=Wall Mount
ERROR CODE =C3
ψ
INDOOR 1 STOP 1P
Capacity=3.2kW
TYPE=Floor Mount
No Error
Line 1 indicates the sender and its operating status. Whenever pushing the IN/OUT changeover switch, the
display changes from "Out-Dr" to "INDOOR 0" to "INDOOR 1" ̖,then "Out-Dr". Indoor unit in pair
system is displayed at "INDOOR 1". "INDOOR 0" displays only for the master unit (remote controller
connected units) of multiple systems including twin, triple, double twin, etc.
Out-DrComp=OFF 1P
INV:MultiHTpump
OutDr=HEAT
ALARM =H8
ψ
Out-DrComp=OFF 2P
Frequency= 48Hz
HPS =Normal
ψ
Out-DrComp=OFF 3P
OutDrTH= 35.5 C
HeatEX = 7.0 C
DischTH1= 75.0 C
The line 1 displays the sender and its status and switching page can not change the data displayed. The line
2 and 3 change displaying data whenever pressing the Display changeover switch.
There may be blank line partially when any data has not been received to be displayed in the line.
In some case, data ca not be received due to different type sending data depending on model or transmission
version.
Sender
Indoor unit in pair system is
displayed on INDOOR 1.
Page No.
The LCD does not display
data not received.
Dis
p
la
y
for outdoor unit
Display for indoor unit 0
(master unit)
Display for indoor unit 1
(slave unit)
Display for Page 1
Display for Page 2 Display for Page 3