6-4 Meaning of Abbreviation
Transmission from outdoor unit to indoor unit
Abbreviations
in English
Meaning
Abbreviations
in English
Meaning
Active ON Htpump Heat pump
ALARM ON INV Inverter
CAUTION CAUTION ERROR Multi Multi system
Comp TH Compressor head temperature no data No data
Cool Cooling only unit No Error No malfunction
Current Input current Non: Non-inverter
DEFROST In defrost operation
Normal
Normal resetnormal status
Disch P Discharge pressure OPERATION In operation
DischTH1 Discharge temperature 1 Out Fan Outdoor unit fan
DischTH2 Discharge temperature 2 Out Fan1 Speed of outdoor unit fan1
DRY Dry operation Out Fan2 Speed of outdoor unit fan2
ERROR CODE Malfunction code OutDr Outdoor unit
FIN TH Radiation fin temperature OutDrTH Outdoor temperature
Frequency Compressor operating frequency Pair Pair system
HEAT Heating operation STOP/Free In stop mode
Heat EX Heat exchanger temperature SuctionTH Suction temperature
Hot Only Heating only unit Th-off Er Thermostat-OFF error
HPS High pressure protection device
Transmission from indoor unit to outdoor unit
Abbreviations
in English
Meaning
Abbreviations
in English
Meaning
ACT ON LEVEL Operation level
Actuate ON LevelH Level high
Built in Built-in type LevelL Level low
Built in Hi Built-in Hi type
Liquid Th Indoor unit liquid pipe temperature
(for multi system)
Capacity Cooling capacity Low Noise Low noise instruction
Ceil Casset Ceiling mounted cassette type NewWallMont New wall mounted type
CeilCasset2 Ceiling suspended, double flow type NoCMD toNEXT No command to next room
CeilConceal Ceiling concealed type Non Non
CeilSuspend Ceiling suspended type OFF Not activated
Circulator Circulator ON ON
CMDto NextRM With command to next room Out FAN CMD Demand for outdoor unit fan
Cntrl TH Remote controller temperature Out-DrComp Status of outdoor unit compressor
Concealed Concealed type
P0P6
Flap position
COOL Cooling operation PeakCut Peak cut status
Corner Corner type
PeakCut/Freez=OK Peak cut and freeze-up protection
are not activated (normal)
DEMAND Demand
PeakCut/Frez=ACT Peak cut and freeze-up protection
are activated.malfunction
dif tmp
Difference between remote controller set
value and room temperature.
PMT Permission
DRY Dry operation PowerSave Power save
ERROR CODE Malfunction code
PowerSelect Current restriction by power
selection
FAN Fan operation PRT Prohibition
FAN Fan operating status
Req realHz Direct operating frequency
instruction
Flap Flap status
Required Hz Indoor unit demand operating
frequency
Floor Mount Floor mounted type Room Th Room temperature
FloorCnceal Floor concealed type
SubUNIT Prot Slave unit in peak cut and freeze-up
protection status
Forced Thrmo Forced thermostat OFF
SubUNIT PrtctACT Peak cut and freeze-up protection
actuated on slave unit (malfunction)
FreezPRT In freeze-up protection status
SubUNIT_Prtct=OK Peak cut and freeze-up protection
for slave unit in normal status
Heater Heater SW Swing status
HOT Heating operation Thermo Thermostat demand
HOT WT Hot water supply operation TYPE Type
HtEX Th Indoor unit heat exchanger temperature unknown Unknown
HtEx Th2 Indoor unit heat exchanger 2 temperature Venti. Ventilation operation
INDOOR Indoor unit Wall Mount Wall mounted type
IntakeTH Indoor unit suction temperature WallConceal Wall concealed type
Jet TH Indoor unit discharge temperature