Daikin FT25JV1B Manual de instalación Pagina 5

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 31
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 4
4
1Application
This operation manual describes Transmission Monitor RSUK0919 (hereinafter referred to the Transmission
Monitor) developed by Daikin Industries, Ltd.
2Outline
Daikin’s air conditioners carry out communication between indoor and outdoor units. The communication data
can serve as very useful information when conducting problem diagnosis. Transmission Monitor RSUK0919
received the data to indicate it on LCD. The Transmission Monitor is featured as follows.
(1) Since the power supply is provided from the product to be monitored, no extra power supply, battery, etc.
is required.
(2) Applicable to voltage ranging from 100V to 240V (50/60 Hz).
(3) Since the changeover of transmission methods is automatically judged, users are only required to connect
the Transmission Monitor to the product.
(4) IN/OUT Changeover Switch : Serves to switch the sender (Outdoor or Indoor unit ࡮࡮Maximum four
indoor units may be connected depending on the circumstances) of data to be displayed.
(5) Display Changeover Switch : Serves to switch pages displaying the data.
(6) The data can be displayed in Japanese or English, which can be switched by an internal jumper. (Factory
setting is English)
3Applicable models
The Transmission Monitor is applicable to products performing the data transmission between indoor and
outdoor unit through three- wire system among sprit & multi air conditioners and Skyair units developed by
Daikin Industries, Ltd.
-Representative models of applicable/non applicable models are shown in the list in the next page. All models
cannot be described in the list. To judge whether the model is applicable or not, confirm the wiring diagram
of product.
-Reference wiring diagram is shown in the page 6.
-Figure 1 and 2 show examples of applicable model. Figure 3 shows an example of non applicable model.
Even the product performs data transmission through 3-wire system, it cannot be determined as an
applicable mode when ON/OFF operation is controlled by relay circuit.
-The models carrying out transmission of digital communication with transmission circuit and receiving
circuit using photo-triac and photo-coupler (see figure 1) are applicable models.