Daikin RKS20E2V1B Manual de usuario Pagina 8

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 27
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 7
3
1
2
Split Sky Air • Outdoor Units
8
Outdoor Units • R-410A • RKS-E2V1B
2 Specifications
Refrigerant Oil Type FVC50K
Charged Volume l 0.375 0.375 0.375
Piping
connections
Liquid (OD) Diameter
(OD)
mm 6.35 6.35 6.35
Gas Diameter
(OD)
mm 9.5 9.5 9.5
Drain Diameter
(OD)
mm 18 18 18
Piping Length Maximum m 20 20 20
Chargele
ss
m1010
Additional Refrigerant
Charge
kg/m 0.02/>10m
Installation
height
difference
Maximum m 15 15 15
Heat Insulation Both liquid and gas pipes
Standard
Accessories
Item Installation manual
Quantity 1 1 1
Notes Nominal cooling capacities are based on : indoor temperature : 270CDB, 190CWB, outdoor temperature : 350CDB,
equivalent refrigerant piping : 7.5m, level difference : 0m.
2-3 ELECTRICAL SPECIFICATIONS RKS20E2V1B RKS25E2V1B RKS35E2V1B
Power Supply Name V1
Phase 1 1 1
Frequency Hz 50 50 50
Voltage V 220-240
Current Nominal
running current
(RLA)
Cooling
(A)
A 2.44 3.14 4.42
Starting current
(cooling/heating)
A2.8 3.5 4.8
Maximum Running Current A 3.33 4.61
Wiring
connections
For Power
Supply
Quantity 3 3 3
For connection
with indoor
Quantity 4 4 4
Remark (including earth wiring)
2-2 TECHNICAL SPECIFICATIONS RKS20E2V1B RKS25E2V1B RKS35E2V1B
Vista de pagina 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 26 27

Comentarios a estos manuales

Sin comentarios