Daikin FTXG35CVMBS Especificaciones Pagina 168

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 194
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 167
Si04-402 Outdoor Unit
Removal Procedure 159
2.3 Removal of Reactor and Partition Plate
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
Remove the outer panels.
Remove the electrical
box.
1. Remove the reactor.
1
Loosen the screw.
Lift and remove the
reactor.
2. Remove the partition
plate.
1
Loosen the 2 screws.
Vista de pagina 167
1 2 ... 163 164 165 166 167 168 169 170 171 172 173 ... 193 194

Comentarios a estos manuales

Sin comentarios