Daikin BRC24Z8 Especificaciones Pagina 7

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 22
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 6
7
Due to ongoing product development, specifications are subject to change without notice.
For additional information on products in this table refer to notes on page 17.
Indoor Unit FDXS25CVMA FDXS35CVMA FDXS50CVMA FDXS60CVMA
Outdoor Unit RXS25EBVMA RXS35EBVMA RXS50FBVMA RXS60FBVMA
Rated Capacity
Cool (kW) 2.4 3.4 5.0 6.0
Heat (kW) 3.2 4.0 5.8 7.0
Capacity Range
Cool (kW) 1.2-3.0 1.2-3.8 1.7-5.3 1.7-6.5
Heat (kW) 1.2-4.5 1.2-5.0 1.7-6.0 1.7-8.0
Power Input (Rated)
Cool (kW) 0.69 1.09 1.65 2.13
Heat (kW) 0.91 1.18 1.92 2.32
E.E.R./C.O.P. C/H 3.48/3.52 3.12/3.39 3.03/3.02 2.82/3.02
Air Flow Rate (Rated) l/s 158 167 200 266
Indoor Sound Level (@1.5m) dBA 35 35 37 38
ESP Settings Pa 40 40 40 40
Indoor Fan Speeds 5 steps, quiet & automatic
Dimensions
(H x W x D)
Indoor (mm) 200 x 900 x 620 200 x 900 x 620 200 x 900 x 620 200 x 1100 x 620
Outdoor (mm) 550 x 765 x 285 550 x 765 x 285 735 x 825 x 300 735 x 825 x 300
Weight
Indoor (kg) 25 25 27 30
Outdoor (kg) 34 34 48 48
Power Supply Ø/V/HZ 1 phase, 220-240V, 50Hz
Compressor Type Hermetically sealed swing type
Refrigerant R410A
Refrigerant Control Electronic Electronic
Refrigerant Pipe Size
Liq (mm) Ø 6.4 (Flared) Ø 6.4 (Flared)
Gas (mm) Ø 9.5 (Flared) Ø 12.7 (Flared)
Drain Pipe Size VP20 (OD 26,ID 20) VP20 (OD 26,ID 20)
Supply Air Conn mm 153 x 860 (Flange) 153 x 860 (Flange) 153 x 1060 (Flange)
Return Air Conn mm 180 x 800 (Flange) 180 x 800 (Flange) 180 x 1000 (Flange)
Max Actual Pipe Length m 20 20 30 30
Max Level Difference m 15 15 20 20
Pre Charged Length m 10 10 10 10
Outdoor Operating Range
Cool (°CDB) 10 to 46 10 to 46 10 to 46 10 to 46
Heat (°CWB) -10 to 20 -10 to 20 -15 to 18 -15 to 18
Outdoor Sound Level (H)
@ 1 Metre from front of unit
Pressure dBA (C/H) 47/48 47/48 47/48 49/49
EPA Sound Power Level Outdoor (dBA) 63 63 62 63
MEPS
COMPLIANT
MINIMUM ENERGY PERFORMANCE STANDARDS
FDXS25/35/50/60CVMA RXS25/35EBVMA RXS50/60FBVMA
INDOOR UNIT OUTDOOR UNIT
DKA0613_DuctedBro_April09_GF_V6.indd 7 3/4/09 11:06:52 AM