Daikin BRC24Z8 Especificaciones Pagina 21

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 22
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 20
21
5
6
7
1234
23
22
21
20 19 18 17 16 15
8
9
10
12
13
14
11
Controlled Comfort
at your fingertips
1
ON/OFF BUTTON
Press the ON/OFF button to start or
stop the system.
2
OPERATION LAMP
The operation lamp lights up during
operation or blinks if a malfunction
occurs.
3
LEAVE HOME ICON
Shows the status of the Leave
Home function.
ON Leave Home is enabled
FLASHING Leave Home is active
OFF Leave Home is disabled
4
OPERATION MODEL ICON
These icons indicate the current
operation mode (cooling, heating,
automatic changeover, program
dry, fan only).
5
MAXIMUM SET TEMPERATURE
When in limit operation,
this indicates the maximum
temperature that can be set
on the controller.
6
SCHEDULE TIMER AND
ACTION ICON
This indicates that the schedule
timer is active and displays the
actions for each day.
7
MINIMUM SET TEMPERATURE
When in limit operation,
this indicates the minimum
temperature that can be set
on the controller.
8
DAY OF THE WEEK INDICATOR
Shows the current week day
or the set day when reading or
programming the schedule timer.
9
CLOCK DISPLAY
Indicates the current time or
the action time when reading or
programming the schedule timer.
10
FAN SPEED ICON
Indicates the set fan speed.
11
SET TEMPERATURE DISPLAY
Indicates the current set
temperature.
12
NOT AVAILABLE
Displayed whenever a non installed
function is selected.
13
FAN SPEED BUTTON
Selects between available fan
speeds.
14
AIR FLOW DIRECTION ADJUST
BUTTON
Adjusts air flow discharge direction
(not available on ducted units).
15
OPERATION CHANGE/MIN-MAX
BUTTON
This is a multi purpose button.
Depending on the previous
manipulations of the user, it can
have the following functions.
a. Select the operation model of
the installation (cooling-heating-
dry-fan only).
b. Toggles between the minimum
and maximum temperature when
in limit operation.
16
SET POINT/LIMIT BUTTON
Toggles between set point, limit
operation or OFF (programming
mode only).
17
TEMPERATURE ADJUST BUTTONS
Used to adjust the current
set temperature or, when in
programming mode, to adjust the
programmed set point temperature.
18
TIME ADJUST BUTTON
Used to adjust the clock or, when in
programming mode, to adjust the
programmed action time.
19
SCHEDULE TIMER BUTTON
Enables or disables the schedule
timer.
20
PROGRAMMING BUTTON
This is a multi purpose button.
Depending on the previous
manipulations of the user, the
programming button can have
various functions.
21
INSPECTION/TEST OPERATION
BUTTON
Not used – for service purposes only.
22
VENTILATION VOLUME BUTTON
Active only when used in
conjunction with a Daikin heat
reclaim ventilator (HRV).
23
VENTILATION MODE BUTTON
Active only when used in
conjunction with a Daikin heat
reclaim ventilator (HRV).
Excludes FDXS models
The BRC1D619 is a state of the art remote controller that offers
full control over your installation.
With Daikin fully ducted air conditioners, you have total control of your
comfort. The BRC1D619 is a state of the art remote controller that
offers full control over your installation.
The basic control functions include turning your system on or off,
switching between the operating modes and temperature and air
volume adjustment. The controller also has a clock and day of the
week indicator.
In addition, the controller features a built-in time clock for the
convenience of automated operation. Up to five actions per day
(totalling 35 actions) can be programmed into the controller and
can be linked to a set temperature, LIMIT operation or off command.
The timer can be enabled or disabled at any time.
Limit operation provides thermostat control within the range of the
set minimum and maximum temperature. The minimum temperature
setting will trigger heating; the maximum temperature setting will
trigger cooling.
The leave home function if activated prevents the room temperature
from dropping when the occupants are out for a longer period. If the
room temperature drops below 10°C, heating is started automatically.
As soon as 15°C is reached, the controller returns to its original status.
Three hierarchical permission levels can be set to limit the user action
if required.
OPTIONAL INFRA-RED WIRELESS
REMOTE CONTROLLER BRC4C62
OPTIONAL ACCESSORIES
BRC1D619 – full function LCD wired remote controller
Programmable 7-day timeclock with temperature set-back control
BRC230Z4 for up to four zones (230 – 240 volt damper motors)
BRC230Z8 for up to eight zones (230 – 240 volt damper motors)
BRC24Z4 for up to 4 zones (24 volt damper motors)
BRC24Z8 for up to 8 zones (24 volt damper motors)
BRCSZC – second slave controller ideal for double storey or larger homes
BRC2A51 – simple LCD wired remote controller
BRC4C62 – infra-red wireless remote controller kit
AKRCSO1-1 – room mounted remote temperature sensor
KRP1B5X – adaptor PCB for field supplied electric booster heater and
outside air fan interlock
KRP4A51 – adaptor PCB for external control (e.g. timelock, BMS)
DCS302CA61 – centralised controller for up to 64 groups
DST301BA61 – programmable Schedule Timer
DTA102A52 – interface PCB for central control
KKPJ5F180 – drain plug connection for outdoor units (RZQ71F, RZQ4P,
R(Z)Q100/125/160K)
KKP937A4 – drain plug connection for outdoor units, (RXS50F, RXS60F)
KHBK – indoor unit hanging kit (for suspending from rafters or slabs) for
FDYQ(N)71-160
KRP58M51 – demand adaptor
DASMS05 – Daikin i-text
KWC26C280 – drain plug kit to suit RZYQ8
KWC26C450 – drain plug kit to suit RZQ10
DKA0613_DuctedBro_April09_GF_V6.indd 21 3/4/09 11:05:36 AM