
Airflow
distribution
Creates uniform
comfort throughout
the space
Comfort enhanced by Round Flow!
With uniform temperature
distribution
Enhanced Comfort
Greater comfort
Improved energy saving
• Condition after exposure
to the smoke of 600
cigarettes in 1 m
3
enclosed space.
Treated
surface
Untreated
surface
Grimy
surface
Resists
soiling
External panels are treated with a coating that
repels dirt.
Mould-proof drain pan includes a silver ion
antibacterial agent that assists in
preventing the growth of slime, bacteria,
and mould that cause smells and clogging.
Avoids uneven temperature and discomfort caused by drafts.
To prevent dirt sticking to the
external panels, they have
been coated with a surface
treatment.
Because air flows out from corner outlets, comfort spreads more widely.
360° airflow Air movement is gentle with Round Flow
Condensation does not easily form on
and dirt does not cling to non-flocking
flaps.
It is easy to clean.
Non-flocking flapsSilver ion anti-bacterial
drain pan
Prevents mould and microorganisms
growing out of the dust and moisture
that adheres to the filters.
Filter has anti-mould and
bactericidal treatment
Grime prevention and bactericidal coating: Make cleaning easier.
Adapts easily to the installation space.
Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing material (option) must be used to
close each unused outlet.
3-way flow
L-shaped
2-way flow
Opposite
2-way flow
(E.g., installed in
a corner)
(E.g., installed in
a long room)
(E.g., installed
near a wall)
(E.g., installed in
middle of ceiling)
4-way flow also possible.
All-round flow
360° airflow can
maintain comfort
even if air
discharge speed is
lower.
Typical flow patterns There are a total of 23 flow patterns.
If you raise the set
temperature by 1 to
1.5°C,and velocity is
decreased by 25%,
you still obtain the same
feeling temperature and
comfort.
Operation sound increases when using 2-way or 3-way flow.
• •
---
• • •
*1 --- --- *2
•
*2
• • •
*2
• • • • • • • • • •
*2
Cleanliness
Comfort Work & Servicing Control features
Others
Options
Features
Accessory required for indoor unit.
Option
*
1
Applicable when wired remote controller is used
*
2
For the outdoor units
*
3
Applicable when BRC1E62 is used
*
4
Applicable when BRC1C61 is used
CEILING MOUNTED CASSETTE TYPE
FCQ50/60LUV1V
FCQ60/71/100/125/140LUV1
Swing pattern selection
Draft prevention function
(heating)
Switchable fan speed
(2 step)
Auto swing
Programme "Dry"
High ceiling application
Night quiet operation
Drain pump mechanism
•
Silver ion anti-bacterial
drain pan
•
Anti-bacterial air filter
Pre charged for
up to 30 m
Long-life filter
Filter sign
Ceiling soiling prevention
Low gas pressure
detection
Emergency operation
Self-diagnosis function
Ultra long-life filter
•
High-efficiency filter
Fresh air intake kit
Control by 2 remote
controllers
Auto-restart
Group control by 1 remote
controller
External command
control
Central remote control
Interlock control
•
DIII-NET communication
standard
Anti corrosion treated
heat exchangers
Two selectable
temperature-sensors
Hot start (after defrost)
Year-round cooling
applicable
Round Flow
BRC1E62
Navigation Remote Controller
(Wired Remote Controller)
BRC7F633F
BRC7F632F
A signal receiver must be added to the indoor unit.
Wireless remote controller and signal
receiver unit are sold as a set.
Wireless LCD remote controller
Signal receiver unit
(Installed type)
Note: Remote controller cable not
included. Cables must be
procured locally.
Note: Remote controller cable not
included. Cables must be
procured locally.
Wired LCD remote controller
BRC1C61
9 10
Remote controller
*3 *3 *3 *3 *4
• • • • • •
*1
• •
*2
•
*2
• • •
*2
• • • •
---
Auto-cooling/heating
change-over
• • • • • • •
*2
•• ••
*3 *3 *3 *3 *4
Setpoint range set
Weekly schedule timer
Setpoint auto reset
Off timer (programmed)
On/Off timer
Cassette air conditioner with 360°
uniform airflow sets the standard
Cassette air conditioner with 360°
uniform airflow sets the standard
Cooling only / Heat pump
Cooling only
Heat pump
Cooling only
Heat pump
Comentarios a estos manuales