7 8
Comfortable currents of air
are sent to every corner of
the room.
Simultaneous twin multi operation
Simultaneous twin multi operation
Simultaneous twin multi operation
Refrigerant branch
piping kit for Twin Multi
operation
2 sets of Twin Multi
For example, four indoor units
are judiciously spaced in this wide
single-floor restaurant to deliver comfortable
currents of air to every corner of the room.
Achieved higher COP
Energy saving
Energy saving
New types of indoor units
New types of indoor units
New types of indoor units
COP is equal to capacity (kW) divided by power consumption (kW), and the larger the COP value, the higher the energy
efficiency, enabling cooling and heating with less electricity and increasing the energy saving performance.
Note :
*Rated cooling capacities are based on
the following conditions: Indoor temp.,
27°CDB, 19.0°CWB; outdoor temp.
35°CDB, 24.0°CWB. Equiv.
refrigeration piping, 7.5 m (horizontal).
What is COP
(Coefficient of Performance)
COP
2
3
4
FCQ50LUV1V
RZR50LUV1V
Cooling*
FCQ140LUV1
RZR140LVVM
2.85
Cooling*
FCQ125LUV1
RZR125LVVM
3.40
Cooling*
FCQ100LUV1
RZR100LVVM
3.60
Cooling*
FCQ71LUV1
RZR71LVVM
3.57
Cooling*
FCQ60LUV1V
RZR60LUV1V
3.70
Cooling*
CEILING MOUNTED
CASSETTE TYPE
Round Flow
Non-inverter
Inverter
Time
Running
current
Starting
current
Time
Running
current
CurrentCurrent
At startup, full power is used to achieve the set temperature quickly.
Then, the capacity is adjusted according to the outdoor temperature
changes and subtle indoor load changes to achieve fine capacity
control resulting in a more stable room temperature.
Non-inverter type
air conditioners
must be switched
on and off
repeatedly,
causing large
fluctuations of
the room
temperature.
Inverter performs variable control of frequency,
which determines air conditioner’s power
performance.
Enhanced comfort with Inverter
Small temp.
difference
Cools a room
in less time
Cooling operation
Inverter power control
Non-inverter type air conditioner
Time
Temp
Set temp
Comfortable
Comfortable
At startup, inverter
raises frequency
smoothly, eliminating
the starting current
spike.
Total of 104 combinations!
Wider lineup of inverters
Wider lineup of inverters
Wider lineup of inverters
Daikin meets your needs with this full lineup of inverters
for various types of indoor units and power supplies.
CEILING MOUNTED
CASSETTE TYPE
Round Flow
COMPACT MULTI FLOW CEILING
MOUNTED CASSETTE TYPE
CEILING MOUNTED CASSETTE TYPE
Round Flow
CEILING SUSPENDED TYPE
CEILING MOUNTED
SLIM DUCT TYPE
DUCT CONNECTION MIDDLE
and HIGH STATIC PRESSURE
TYPE
CEILING MOUNTED BUILT-IN TYPE
FLOOR STANDING TYPE
DUCT CONNECTION MIDDLE and
HIGH STATIC PRESSURE
TYPE
CEILING SUSPENDED TYPE
FLOOR STANDING TYPE
PairTwin
503525 60 71 100 125 140
: Heat pump: Cooling only
1 Phase
1 Phase
3 Phase
1 Phase
3 Phase
1 Phase
1 Phase
1 Phase
3 Phase
1 Phase
3 Phase
1 Phase
3 Phase
1 Phase
3 Phase
1 Phase
3 Phase
1 Phase
3 Phase
Page 28
3.84
Ceiling
mounted slim duct
type
2.5-6.0 kW class
Ceiling suspended type
14.0 kW class
NEWNEW
Comentarios a estos manuales