Daikin ATX20JV1B Especificaciones

Busca en linea o descarga Especificaciones para Acondicionadores de aire del sistema de división Daikin ATX20JV1B. Daikin ATX20JV1B Specifications [en] [es] Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 156
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente

Indice de contenidos

Pagina 1 - Inverter Pair

SiBE041010[Applied Models] Inverter Pair : Heat PumpInverter PairWall Mounted Type J-Series

Pagina 2 - J-Series

Introduction SiBE041010ix1.2 Used IconsIcons are used to attract the attention of the reader to specific information. The meaning of each icon is desc

Pagina 3 - Table of Contents ii

Check SiBE04101090 Service Diagnosis5. Check5.1 How to Check5.1.1 Electronic Expansion Valve CheckCheck No.04 Conduct the followings to check the elec

Pagina 4

SiBE041010 CheckService Diagnosis 915.1.2 Four Way Valve Performance CheckCheck No.05(R11965)NOYESYESNOTurn off the power and turn it on again.Disconn

Pagina 5 - Table of Contents iv

Check SiBE04101092 Service Diagnosis5.1.3 Thermistor Resistance CheckCheck No.06 Disconnect the connectors of the thermistors from the PCB, and measur

Pagina 6 - 1. Introduction

SiBE041010 CheckService Diagnosis 935.1.4 Installation Condition CheckCheck No.075.1.5 Discharge Pressure CheckCheck No.08Installation condition check

Pagina 7

Check SiBE04101094 Service Diagnosis5.1.6 Outdoor Fan System CheckCheck No.09 DC motor5.1.7 Power Supply Waveforms CheckCheck No.10 Measure the power

Pagina 8

SiBE041010 CheckService Diagnosis 955.1.8 Inverter Units Refrigerant System CheckCheck No.115.1.9 Power Module CheckCheck No.13Note: Check to make sur

Pagina 9

Check SiBE04101096 Service Diagnosis5.1.10 Rotation Pulse Check on the Outdoor Unit PCBCheck No.15 <Outdoor fan motor>1. Check that the voltage

Pagina 10 - 1.2 Used Icons

SiBE041010 CheckService Diagnosis 975.1.11 Indoor Unit PCB Output CheckCheck No.18 (1) Check the connector for connection.(2) Check the motor control

Pagina 11 - List of Functions

Check SiBE04101098 Service Diagnosis5.1.13 Fan Motor Wire / Short Circuit CheckCheck No.20 (1) Check the connector for connection.(2) Turn the power o

Pagina 12 - 1. Functions

SiBE041010 CheckService Diagnosis 995.1.14 Main Circuit Short CheckCheck No.29Note: Check to make sure that the voltage between (+) and (–) of the dio

Pagina 13 - Specifications

SiBE041010List of Functions 1Part 1List of Functions1. Functions...

Pagina 14 - 1. Specifications

SiBE041010100 Removal ProcedurePart 7Removal Procedure1. Indoor Unit...

Pagina 15 - 50 Hz, 230 V

SiBE041010 Indoor UnitRemoval Procedure 1011. Indoor Unit1.1 Removal of Air FilterProcedure Warning Be sure to wait 10 minutes or more after turning o

Pagina 16

Indoor Unit SiBE041010102 Removal Procedure3Pull out the air filter downward and remove it.3. Remove the Titanium apatite photocatalytic air-purifying

Pagina 17

SiBE041010 Indoor UnitRemoval Procedure 1031.2 Removal of Horizontal Blades / Fan GuardProcedure Warning Be sure to wait 10 minutes or more after turn

Pagina 18 - Connector Wiring Diagram

Indoor Unit SiBE041010104 Removal Procedure5Remove the horizontal blade.2. Remove the fan guard.1Unfasten the hooks at the lower part of the fan guard

Pagina 19 - 1.1 Indoor Unit

SiBE041010 Indoor UnitRemoval Procedure 1051.3 Removal of Front PanelProcedure Warning Be sure to wait 10 minutes or more after turning off all power

Pagina 20 - PCB(2): Display PCB

Indoor Unit SiBE041010106 Removal Procedure1.4 Removal of Front GrilleProcedure Warning Be sure to wait 10 minutes or more after turning off all power

Pagina 21

SiBE041010 Indoor UnitRemoval Procedure 1073Press each hook, and also lift the grille up to unfasten the hooks.4Pull the upper part of the front grill

Pagina 22 - PCB(2): Main PCB

Indoor Unit SiBE041010108 Removal Procedure1.5 Removal of Electrical Box / Vertical BladesProcedure Warning Be sure to wait 10 minutes or more after t

Pagina 23 - Function and Control

SiBE041010 Indoor UnitRemoval Procedure 1092. Remove the electrical box.1Remove the screw and disconnect the earth wire.2Disconnect the connector for

Pagina 24 - 1. Main Functions

Functions SiBE0410102 List of Functions1. FunctionsCategory FunctionsFTX20/25/35JV1BRX20/25/35JV1BATX20/25/35JV1BARX20/25/35JV1BCategory FunctionsFTX2

Pagina 25

Indoor Unit SiBE041010110 Removal ProcedureThere is a hook on the bottom frame. When reassembling, fit the rear side of the electrical box to the hoo

Pagina 26 - 1.2 Airflow Direction Control

SiBE041010 Indoor UnitRemoval Procedure 1111.6 Removal of PCB / Swing MotorProcedure Warning Be sure to wait 10 minutes or more after turning off all

Pagina 27 - (R11975)

Indoor Unit SiBE041010112 Removal Procedure5Disconnect the wire harnesses from the terminal board with pliers.2. Remove the display PCB.1Lift the lowe

Pagina 28 - 1.4 Program Dry Operation

SiBE041010 Indoor UnitRemoval Procedure 1132Disconnect the connector [S27] from the display PCB.3The figure shows the names of the display PCB compone

Pagina 29 - 1.5 Automatic Operation

Indoor Unit SiBE041010114 Removal Procedure4Unfasten the 2 hooks at the upper part from the rear side.5Lift up the upper part of the control PCB, and

Pagina 30 - 1.6 Thermostat Control

SiBE041010 Indoor UnitRemoval Procedure 1151.7 Removal of Indoor Heat ExchangerProcedure Warning Be sure to wait 10 minutes or more after turning off

Pagina 31 - 1.7 NIGHT SET Mode

Indoor Unit SiBE041010116 Removal Procedure5Disconnect the flare nut for liquid piping with 2 wrenches.2. Remove the indoor unit.When the pipings are

Pagina 32 - 1.8 ECONO Operation

SiBE041010 Indoor UnitRemoval Procedure 1173Widen the auxiliary piping to the extent of 10°~20°. 4Remove the screw on the left side and unfasten the h

Pagina 33 - 3. POWERFUL operation is OFF

Indoor Unit SiBE041010118 Removal Procedure1.8 Removal of Fan RotorProcedure Warning Be sure to wait 10 minutes or more after turning off all power su

Pagina 34 - 1.10 Other Functions

SiBE041010 Indoor UnitRemoval Procedure 1192. Remove the fan rotor and fan motor.1The fan motor has 3 projections.The fan rotor has a rotating shaft o

Pagina 35 - 2. Function of Thermistor

SiBE041010Specifications 3Part 2Specifications1. Specifications ...

Pagina 36 - 3. Control Specification

Indoor Unit SiBE041010120 Removal Procedure5Unfasten the 2 hooks of the motor cover.6Pull out the fan motor from the fan rotor to remove.The magnet o

Pagina 37 - 3.2 Frequency Control

SiBE041010 Indoor UnitRemoval Procedure 1211.9 Exchange of Drain HoseProcedure Warning Be sure to wait 10 minutes or more after turning off all power

Pagina 38

Outdoor Unit SiBE041010122 Removal Procedure2. Outdoor Unit2.1 Removal of PanelsProcedure Warning Be sure to wait 10 minutes or more after turning off

Pagina 39 - 3.3.1 Preheating Operation

SiBE041010 Outdoor UnitRemoval Procedure 1232Remove the 3 screws (right: 1 screw, left: 2 screws) and remove the top panel.3Remove the 6 screws of the

Pagina 40 - 3.3.4 3-minute Standby

Outdoor Unit SiBE041010124 Removal Procedure2.2 Removal of Outdoor Fan / Fan MotorProcedure Warning Be sure to wait 10 minutes or more after turning o

Pagina 41 - 3.5 Input Current Control

SiBE041010 Outdoor UnitRemoval Procedure 1252.3 Removal of Electrical Box / Control PCBProcedure Warning Be sure to wait 10 minutes or more after turn

Pagina 42 - 3.7 Heating Peak-cut Control

Outdoor Unit SiBE041010126 Removal Procedure5Unfasten the hook on the rear side.When reassembling, make sure to fit the hook.6Unfasten the hook, and

Pagina 43 - 3.8 Outdoor Fan Control

SiBE041010 Outdoor UnitRemoval Procedure 1273Disconnect the connector for electronic expansion valve coil [S20].4Detach the clamp of the lead wire for

Pagina 44 - 3.10 Defrost Control

Outdoor Unit SiBE041010128 Removal Procedure7Pull out the outdoor heat exchanger thermistor.Pay attention so as not to lose the clip.8Cut the clamp.9

Pagina 45 - Function and Control 35

SiBE041010 Outdoor UnitRemoval Procedure 1293. Remove the control PCB.1Remove the screw on the terminal board.2Cut the clamp.3Remove the 2 screws of t

Pagina 46 - 36 Function and Control

Specifications SiBE0410104 Specifications1. Specifications50 Hz, 230 VNote: The data are based on the conditions shown in the table below.ModelIndoor

Pagina 47 - Function and Control 37

Outdoor Unit SiBE041010130 Removal Procedure5Remove the 3 screws to remove the reactor.6Disconnect the connector for thermistors [S90].7Remove the 6 s

Pagina 48 - 3.12 Malfunctions

SiBE041010 Outdoor UnitRemoval Procedure 1319Unfasten the 2 hooks.10Lift and remove the control PCB.11Feature of the control PCB[S10] [HN3] [HL3]: fil

Pagina 49 - 3.13 Forced Operation Mode

Outdoor Unit SiBE041010132 Removal Procedure2.4 Removal of Sound BlanketProcedure Warning Be sure to wait 10 minutes or more after turning off all pow

Pagina 50 - Operation Manual

SiBE041010 Outdoor UnitRemoval Procedure 1332Pull the sound blankets (outer and inner 2) out.3Pull the sound blanket (inner 1) out.Since the piping p

Pagina 51 - 1. System Configuration

Outdoor Unit SiBE041010134 Removal Procedure2.5 Removal of Four Way ValveProcedure Warning Be sure to wait 10 minutes or more after turning off all po

Pagina 52 - 2. Operation Manual

SiBE041010 Outdoor UnitRemoval Procedure 1355Remove the putty.2. Remove the four way valve. CautionBe careful not to get yourself burnt with the pipes

Pagina 53 -  To stop operation

Outdoor Unit SiBE041010136 Removal Procedure2Heat up the 3 brazed points of the four way valve. Disconnect the point (b) first.If the gas brazing mach

Pagina 54 - 44 Operation Manual

SiBE041010 Outdoor UnitRemoval Procedure 1372.6 Removal of CompressorProcedure Warning Be sure to wait 10 minutes or more after turning off all power

Pagina 55 - (louvers)

SiBE041010138 OthersPart 8Others1. Others ...1391.1 Tria

Pagina 56 - 〈HEAT〉 The flap will go down

SiBE041010 OthersOthers 1391. Others1.1 Trial OperationOutline 1. Measure the supply voltage and make sure that it falls in the specified range.2. Tri

Pagina 57 - POWERFUL Operation

SiBE041010 SpecificationsSpecifications 550 Hz, 230 VNote: The data are based on the conditions shown in the table below.ModelIndoor Units FTX35JV1BO

Pagina 58 - ECONO Operation

Others SiBE041010140 Others1.2 Field Settings1.2.1 When 2 Units are Installed in 1 RoomHow to set the different addresses.When 2 indoor units are ins

Pagina 59 - TIMER Operation

SiBE041010 OthersOthers 1411.3 Application of Silicon Grease to a Power Transistor and a Diode BridgeApplicable ModelsAll outdoor units using inverter

Pagina 60 -  To use ON TIMER operation

SiBE041010142 AppendixPart 9Appendix1. Piping Diagrams...1431.1 Indoor

Pagina 61 - Service Diagnosis

SiBE041010 Piping DiagramsAppendix 1431. Piping Diagrams1.1 Indoor UnitFTX20/25/35JV1B, ATX20/25/35JV1BREFRIGERANT FLOWHEAT EXCHANGERFIELD PIPING4.8Cu

Pagina 62 - 1. Caution for Diagnosis

Piping Diagrams SiBE041010144 Appendix1.2 Outdoor UnitRX20/25JV1B, ARX20/25JV1BRX35JV1B, ARX35JV1BCOOLINGCOMPRESSORHEATINGFIELD PIPING9.5CuT 9.5CuT7.0

Pagina 63

SiBE041010 Wiring DiagramsAppendix 1452. Wiring Diagrams2.1 Indoor UnitFTX20/25/35JV1B, ATX20/25/35JV1B2.2 Outdoor UnitRX20/25/35JV1B, ARX20/25/35JV1B

Pagina 64 - < ARC433 Series >

WarningDaikin Industries, Ltd.’s products are manufactured for export to numerous countries throughout the world. Daikin Industries, Ltd. does not hav

Pagina 65 - Service Diagnosis 55

Specifications SiBE0410106 Specifications50 Hz, 230 VNote: The data are based on the conditions shown in the table below.ModelIndoor Units ATX20JV1B

Pagina 66 - 56 Service Diagnosis

SiBE041010 SpecificationsSpecifications 750 Hz, 230 VNote: The data are based on the conditions shown in the table below.ModelIndoor Units ATX35JV1BO

Pagina 67 - 4. Troubleshooting

SiBE0410108 Printed Circuit Board Connector Wiring DiagramPart 3Printed Circuit BoardConnector Wiring Diagram1. Printed Circuit Board Connector Wiring

Pagina 68 - Model Type Connector

SiBE041010 Printed Circuit Board Connector Wiring DiagramPrinted Circuit Board Connector Wiring Diagram 91. Printed Circuit Board Connector Wiring Dia

Pagina 69 - Service Diagnosis 59

SiBE041010i Table of ContentsInverter PairWall Mounted TypeJ-SerieszHeat PumpIndoor UnitsFTX20JV1B ATX20JV1BFTX25JV1B ATX25JV1BFTX35JV1B ATX35JV1BOutd

Pagina 70 - Refer to P.92

Printed Circuit Board Connector Wiring Diagram SiBE04101010 Printed Circuit Board Connector Wiring DiagramPCB Detail PCB(1): Control PCBPCB(2): Displa

Pagina 71 - Service Diagnosis 61

SiBE041010 Printed Circuit Board Connector Wiring DiagramPrinted Circuit Board Connector Wiring Diagram 111.2 Outdoor UnitConnectors and Other PartsPC

Pagina 72 - (R12038)

Printed Circuit Board Connector Wiring Diagram SiBE04101012 Printed Circuit Board Connector Wiring DiagramPCB Detail PCB(1): Filter PCBPCB(2): Main PC

Pagina 73 - Service Diagnosis 63

SiBE041010Function and Control 13Part 4Function and Control1. Main Functions...

Pagina 74 - 64 Service Diagnosis

Main Functions SiBE04101014 Function and Control1. Main Functions1.1 Frequency PrincipleMain Control ParametersThe compressor is frequency-controlled

Pagina 75 - Service Diagnosis 65

SiBE041010 Main FunctionsFunction and Control 15Inverter Features The inverter provides the following features:The regulating capacity can be changed

Pagina 76 - 66 Service Diagnosis

Main Functions SiBE04101016 Function and Control1.2 Airflow Direction ControlPower-Airflow FlapThe large flap sends a large volume of air downwards to

Pagina 77 - Service Diagnosis 67

SiBE041010 Main FunctionsFunction and Control 171.3 Fan Speed Control for Indoor UnitsOutline Phase control and fan speed control contains 9 steps: LL

Pagina 78 - 4.10 Compressor Lock

Main Functions SiBE04101018 Function and Control1.4 Program Dry OperationOutline Program dry operation removes humidity while preventing the room temp

Pagina 79 - 4.11 DC Fan Lock

SiBE041010 Main FunctionsFunction and Control 191.5 Automatic OperationOutline Automatic Cooling / Heating FunctionWhen the AUTO mode is selected with

Pagina 80 - 70 Service Diagnosis

SiBE041010Table of Contents ii1. Introduction ...v1.1 Safety

Pagina 81 - Service Diagnosis 71

Main Functions SiBE04101020 Function and Control1.6 Thermostat ControlThermostat control is based on the difference between the room temperature and t

Pagina 82 - 72 Service Diagnosis

SiBE041010 Main FunctionsFunction and Control 211.7 NIGHT SET ModeOutline When the OFF timer is set, the NIGHT SET Mode is automatically activated. Th

Pagina 83 - (R11950)

Main Functions SiBE04101022 Function and Control1.8 ECONO OperationOutline The "ECONO operation" reduces the maximum operating current and p

Pagina 84 - 74 Service Diagnosis

SiBE041010 Main FunctionsFunction and Control 231.9 Inverter POWERFUL OperationOutline In order to exploit the cooling and heating capacity to full ex

Pagina 85 - Service Diagnosis 75

Main Functions SiBE04101024 Function and Control1.10 Other Functions1.10.1 Hot-Start FunctionIn order to prevent the cold air blast that normally come

Pagina 86 - 76 Service Diagnosis

SiBE041010 Function of ThermistorFunction and Control 252. Function of ThermistorA Outdoor Heat Exchanger Thermistor 1. The outdoor heat exchanger t

Pagina 87 - Refer to P.99

Control Specification SiBE04101026 Function and Control3. Control Specification3.1 Mode HierarchyOutline There are two modes; the one is the normal op

Pagina 88 - 78 Service Diagnosis

SiBE041010 Control SpecificationFunction and Control 273.2 Frequency ControlOutline Frequency is determined according to the difference between the ro

Pagina 89 - Service Diagnosis 79

Control Specification SiBE04101028 Function and ControlIndoor Frequency Command (∆D signal)The difference between the room temperature and the target

Pagina 90 - 80 Service Diagnosis

SiBE041010 Control SpecificationFunction and Control 293.3 Controls at Mode Changing / Start-up3.3.1 Preheating OperationOutline The inverter operatio

Pagina 91 - Service Diagnosis 81

SiBE041010iii Table of Contents2.3 Adjusting the Airflow Direction...452.4 POWERFUL Opera

Pagina 92 - Refer to P.94

Control Specification SiBE04101030 Function and Control3.3.4 3-minute StandbyTurning on the compressor is prohibited for 3 minutes after turning it of

Pagina 93 - Service Diagnosis 83

SiBE041010 Control SpecificationFunction and Control 313.5 Input Current ControlOutline The microcomputer calculates the input current during the comp

Pagina 94 - 84 Service Diagnosis

Control Specification SiBE04101032 Function and Control3.6 Freeze-up Protection ControlOutline During cooling operation, the signal sent from the indo

Pagina 95 - Service Diagnosis 85

SiBE041010 Control SpecificationFunction and Control 333.8 Outdoor Fan Control1. Fan OFF delay when stoppedThe outdoor fan is turned OFF 70 seconds af

Pagina 96 - 86 Service Diagnosis

Control Specification SiBE04101034 Function and Control3.10 Defrost ControlOutline Defrosting is carried out by the cooling cycle (reverse cycle). The

Pagina 97 - 4.23 Refrigerant Shortage

SiBE041010 Control SpecificationFunction and Control 353.11 Electronic Expansion Valve ControlOutline The following items are included in the electron

Pagina 98 - Refer to P.90

Control Specification SiBE04101036 Function and Control3.11.1 Fully Closing with Power ONThe electronic expansion valve is initialized when turning on

Pagina 99 - Service Diagnosis 89

SiBE041010 Control SpecificationFunction and Control 373.11.7 Control when frequency is changedWhen the target discharge pipe temperature control is a

Pagina 100 - 5. Check

Control Specification SiBE04101038 Function and Control3.12 Malfunctions3.12.1 Sensor Malfunction DetectionSensor malfunction may occur in the thermis

Pagina 101 - Check No.05

SiBE041010 Control SpecificationFunction and Control 393.13 Forced Operation ModeOutline Forced operation mode includes only forced cooling.DetailItem

Pagina 102 - Resistance range

SiBE041010Table of Contents iv2. Outdoor Unit...1222.1 Removal of

Pagina 103 - Check No.08

SiBE04101040 Operation ManualPart 5Operation Manual1. System Configuration...

Pagina 104 - 94 Service Diagnosis

SiBE041010 System ConfigurationOperation Manual 411. System ConfigurationAfter the installation and test operation of the room air conditioner have be

Pagina 105 - 5.1.9 Power Module Check

Operation Manual SiBE04101042 Operation Manual2. Operation ManualIllustrations are for FTX models as representative.2.1 Remote Controller6 Remote Con

Pagina 106 - 96 Service Diagnosis

SiBE041010 Operation ManualOperation Manual 432.2 AUTO · DRY · COOL · HEAT · FAN Operation10AUTO · DRY · COOL · HEAT · FAN Operation To start operati

Pagina 107 - Service Diagnosis 97

Operation Manual SiBE04101044 Operation Manual11 To change the airflow rate setting5. Press “FAN setting button”.• Indoor unit quiet operationWhen th

Pagina 108 - 98 Service Diagnosis

SiBE041010 Operation ManualOperation Manual 452.3 Adjusting the Airflow Direction12Adjusting the Airflow DirectionYou can adjust the airflow direction

Pagina 109 - (R12025)

Operation Manual SiBE04101046 Operation Manual13 To start COMFORT AIRFLOW operation3. Press “COMFORT AIRFLOW button”.•The flap position will change,

Pagina 110 - Removal Procedure

SiBE041010 Operation ManualOperation Manual 472.4 POWERFUL Operation14POWERFUL Operation1. Press “POWERFUL button”.• POWERFUL operation ends in 20min

Pagina 111 - 1. Indoor Unit

Operation Manual SiBE04101048 Operation Manual2.5 ECONO Operation15ECONO Operation To start ECONO operation1. Press “ECONO button” .• “ ” is disp

Pagina 112

SiBE041010 Operation ManualOperation Manual 492.6 TIMER Operation16TIMER Operation• Check that the clock is correct.If not, set the clock to the pres

Pagina 113

Introduction SiBE041010v1. Introduction1.1 Safety CautionsCautions and WarningsBe sure to read the following safety cautions before conducting repair

Pagina 114 - Fan guard

Operation Manual SiBE04101050 Operation Manual17 To use ON TIMER operation•1. Press “ON TIMER button”.is displayed.blinks.2.•3. Press “ON TIMER butto

Pagina 115 - 1.3 Removal of Front Panel

SiBE041010Service Diagnosis 51Part 6Service Diagnosis1. Caution for Diagnosis...

Pagina 116 - 1.4 Removal of Front Grille

Caution for Diagnosis SiBE04101052 Service Diagnosis1. Caution for Diagnosis1.1 Troubleshooting with LEDIndoor Unit The operation lamp blinks when any

Pagina 117 - Left Center Right

SiBE041010 Problem Symptoms and MeasuresService Diagnosis 532. Problem Symptoms and MeasuresSymptom Check Item Details of Measure ReferencePageThe uni

Pagina 118 - (R11268)

Service Check Function SiBE04101054 Service Diagnosis3. Service Check FunctionCheck Method 1 1. When the timer cancel button is held down for 5 second

Pagina 119 - Earth wire

SiBE041010 Service Check FunctionService Diagnosis 55Check Method 21. Press the center of the TEMP button and the MODE button at the same time.The fig

Pagina 120 - Vertical blade ASSY

Service Check Function SiBE04101056 Service Diagnosis5. Press the TEMP▲ or ▼ button and change the figure until you hear the sound of “beep”.6. Diagno

Pagina 121 - Shield plate (2)

SiBE041010 TroubleshootingService Diagnosis 574. Troubleshooting4.1 Error Codes and Description★: Displayed only when system-down occurs.Error Codes D

Pagina 122 - Step Procedure Points

Troubleshooting SiBE04101058 Service Diagnosis4.2 Indoor Unit PCB AbnormalityRemote Controller DisplayA1Method of Malfunction DetectionThe system chec

Pagina 123

SiBE041010 TroubleshootingService Diagnosis 594.3 Freeze-up Protection Control or Heating Peak-cut ControlRemote Controller DisplayA5Method of Malfunc

Pagina 124

SiBE041010 IntroductionviBe sure to wear a safety helmet, gloves, and a safety belt when working at a high place (more than 2 m). Insufficient safety

Pagina 125 - Connecting wires

Troubleshooting SiBE04101060 Service DiagnosisTroubleshootingCheck No.06Refer to P.92NONONOCheck No. 06Check the indoor heat exchanger thermistor.YESY

Pagina 126 - Piping fixture

SiBE041010 TroubleshootingService Diagnosis 614.4 Fan Motor (DC Motor) or Related AbnormalityRemote Controller DisplayA6Method of Malfunction Detectio

Pagina 127 - (R8041) (R11269)

Troubleshooting SiBE04101062 Service DiagnosisTroubleshootingCheck No.18Refer to P.97Check No.19Refer to P.97Check No.20Refer to P.98(R12038)Turn off

Pagina 128 - 1.8 Removal of Fan Rotor

SiBE041010 TroubleshootingService Diagnosis 634.5 Thermistor or Related Abnormality (Indoor Unit)Remote Controller DisplayC4, C9 Method of Malfunctio

Pagina 129 - Fan motor

Troubleshooting SiBE04101064 Service Diagnosis4.6 Signal Transmission Error (between Indoor and Outdoor Unit)Remote Controller DisplayU4Method of Malf

Pagina 130 - 120 Removal Procedure

SiBE041010 TroubleshootingService Diagnosis 654.7 Unspecified Voltage (between Indoor and Outdoor Unit)Remote Controller Display UAMethod of Malfuncti

Pagina 131 - 1.9 Exchange of Drain Hose

Troubleshooting SiBE04101066 Service Diagnosis4.8 Outdoor Unit PCB AbnormalityRemote Controller Display E1Method of Malfunction DetectionThe system f

Pagina 132 - 2. Outdoor Unit

SiBE041010 TroubleshootingService Diagnosis 674.9 OL Activation (Compressor Overload)Remote Controller DisplayE5Method of Malfunction DetectionA compr

Pagina 133 - Projection (rear side)

Troubleshooting SiBE04101068 Service Diagnosis4.10 Compressor LockRemote Controller DisplayE6Method of Malfunction DetectionA compressor lock is detec

Pagina 134 - Lead wire Outdoor fan

SiBE041010 TroubleshootingService Diagnosis 694.11 DC Fan LockRemote Controller DisplayE7Method of Malfunction DetectionAn error is determined with th

Pagina 135 - Guard net

Introduction SiBE041010vii1.1.2 Cautions Regarding Safety of UsersWarningBe sure to use parts listed in the service parts list of the applicable model

Pagina 136 - Right side panel

Troubleshooting SiBE04101070 Service Diagnosis4.12 Input Overcurrent DetectionRemote Controller DisplayE8Method of Malfunction DetectionAn input overc

Pagina 137 - Discharge pipe thermistor

SiBE041010 TroubleshootingService Diagnosis 714.13 Four Way Valve AbnormalityRemote Controller DisplayEAMethod of Malfunction DetectionThe room temper

Pagina 138 - Electrical box

Troubleshooting SiBE04101072 Service DiagnosisTroubleshootingCheck No.05Refer to P.91Check No.06Refer to P.92Check No.11Refer to P.95 NGOKNOOKNGOKYESN

Pagina 139 - BrownWhite

SiBE041010 TroubleshootingService Diagnosis 734.14 Discharge Pipe Temperature ControlRemote Controller DisplayF3Method of Malfunction DetectionAn erro

Pagina 140 - (R11962)

Troubleshooting SiBE04101074 Service Diagnosis4.15 High Pressure Control in CoolingRemote Controller DisplayF6Method of Malfunction DetectionHigh-pres

Pagina 141 - (R12021)

SiBE041010 TroubleshootingService Diagnosis 754.16 Compressor System Sensor AbnormalityRemote Controller Display H0Method of Malfunction DetectionThe

Pagina 142 - 2.4 Removal of Sound Blanket

Troubleshooting SiBE04101076 Service Diagnosis4.17 Position Sensor AbnormalityRemote Controller DisplayH6Method of Malfunction DetectionA compressor s

Pagina 143 - Procedure Points

SiBE041010 TroubleshootingService Diagnosis 77TroubleshootingCheck No.29Refer to P.99CautionBe sure to turn off the power switch before connecting or

Pagina 144 - 2.5 Removal of Four Way Valve

Troubleshooting SiBE04101078 Service Diagnosis4.18 DC Voltage / Current Sensor AbnormalityRemote Controller DisplayH8Method of Malfunction DetectionDC

Pagina 145 - Removal Procedure 135

SiBE041010 TroubleshootingService Diagnosis 794.19 Thermistor or Related Abnormality (Outdoor Unit)Remote Controller Display H9, J3, J6, P4Method of M

Pagina 146 - 136 Removal Procedure

SiBE041010 IntroductionviiiCheck to make sure that the power cable plug is not dirty or loose, then insert the plug into a power outlet securely.If th

Pagina 147 - 2.6 Removal of Compressor

Troubleshooting SiBE04101080 Service DiagnosisTroubleshooting In case of “H9” “J3” “J6”Check No.06Refer to P.92H9 : Outdoor temperature thermistorJ3 :

Pagina 148 - 138 Others

SiBE041010 TroubleshootingService Diagnosis 814.20 Electrical Box Temperature RiseRemote Controller DisplayL3Method of Malfunction DetectionAn electri

Pagina 149 - 1. Others

Troubleshooting SiBE04101082 Service DiagnosisTroubleshootingCheck No.07Refer to P.93Check No.09Refer to P.94CautionWARNINGTo cool the electrical comp

Pagina 150 - 1.2 Field Settings

SiBE041010 TroubleshootingService Diagnosis 834.21 Radiation Fin Temperature RiseRemote Controller DisplayL4Method of Malfunction DetectionA radiation

Pagina 151 - Others 141

Troubleshooting SiBE04101084 Service DiagnosisTroubleshootingCheck No.07Refer to P.93Check No.09Refer to P.94Note: Refer to “Application of silicon gr

Pagina 152 - Appendix

SiBE041010 TroubleshootingService Diagnosis 854.22 Output Overcurrent DetectionRemote Controller DisplayL5Method of Malfunction DetectionAn output ove

Pagina 153 - 1. Piping Diagrams

Troubleshooting SiBE04101086 Service DiagnosisTroubleshootingCheck No.07Refer to P.93Check No.08Refer to P.93Check No.13Refer to P.95(R12016)CautionNO

Pagina 154 - 1.2 Outdoor Unit

SiBE041010 TroubleshootingService Diagnosis 874.23 Refrigerant ShortageRemote Controller DisplayU0Method of Malfunction DetectionRefrigerant shortage

Pagina 155 - 2. Wiring Diagrams

Troubleshooting SiBE04101088 Service DiagnosisTroubleshootingCheck No.04Refer to P.90Check No.06Refer to P.92(R12015)CautionYESNGNONOYESYESYESNOYESNON

Pagina 156 - Cautions on product corrosion

SiBE041010 TroubleshootingService Diagnosis 894.24 Low-voltage Detection or Over-voltage DetectionRemote Controller DisplayU2Method of Malfunction Det

Comentarios a estos manuales

Sin comentarios