DAIKIN ROOM AIR CONDITIONEROPERATION MANUALEnglishDeutschFrançaisNederlandsEspañolMODELSFTXS20J2V1BFTXS25J2V1BFTXS35J2V1BFTXS42J2V1BFTXS50J2V1B00_CV_3

Pagina 2 - CONTENTS

9English Checks on remote controller settings• This remote controller is common to the heat pump model and cooling only model. Use the DIP switch on t

Pagina 3 - Safety Precautions

10OPERATIONAUTO · DRY · COOL · HEAT · FAN OperationThe air conditioner operates with the operation mode of your choice. From the next time on, the air

Pagina 4 - System relocation

11English To change the airflow rate setting5. Press . • Indoor unit quiet operationWhen the airflow is set to “ ”, the noise from the indoor unit wi

Pagina 5 - Names of Parts

12Adjusting the Airflow DirectionYou can adjust the airflow direction to increase your comfort. To start auto swingPress .• “ ” is displayed on the

Pagina 6 - Outdoor Unit

13English To set the flaps or louvers at desired position • This function is effective while flaps or louvers are in auto swing mode. Press and wh

Pagina 7

14COMFORT AIRFLOW and INTELLIGENT EYE Operation COMFORT AIRFLOW operationThe flow of air will be in the upward direction while in COOL operation and i

Pagina 8 - Preparation before Operation

15English To start operationPress and select the desired mode.• Each time the is pressed a different setting option is displayed on the LCD.• By

Pagina 9

16COMFORT AIRFLOW and INTELLIGENT EYE OperationNOTE Notes on COMFORT AIRFLOW operation • The flap position will change, preventing air from blowing

Pagina 10 - DIP switch

17EnglishNOTEINTELLIGENT EYE operation is useful for energy saving CAUTION Note on combination of COMFORT AIRFLOW operation and INTELLIGENT EYE oper

Pagina 11 - HEAT PUMP

18POWERFUL OperationPOWERFUL operation quickly maximizes the cooling (heating) effect in any operation mode. You can get the maximum capacity. To sta

Pagina 12 - 5. Press

1EnglishCONTENTSREAD BEFORE OPERATIONSafety Precautions ... 2Names of Parts ...

Pagina 13 - To start auto swing

19EnglishOUTDOOR UNIT QUIET OperationOUTDOOR UNIT QUIET operation lowers the noise level of the outdoor unit by changing the frequency and fan speed o

Pagina 14 - CAUTION

20ECONO OperationECONO operation is a function which enables efficient operation by limiting the maximum power consumption value. This function is use

Pagina 15 - INTELLIGENT EYE Operation

21EnglishOFF TIMER OperationTimer functions are useful for automatically switching the air conditioner on or off at night or in the morning. You can a

Pagina 16 - COMFORT

22ON TIMER Operation To use ON TIMER operation • Check that the clock is correct. If not, set the clock to the present time. (page 8.) 1. Press .• “

Pagina 17

23EnglishWEEKLY TIMER OperationUp to 4 timer settings can be saved for each day of the week. It is convenient if the WEEKLY TIMER is set according to

Pagina 18

24WEEKLY TIMER Operation To use WEEKLY TIMER operation • Make sure the day of the week and time are set. If not, set the day of the week and time. (pa

Pagina 19 - POWERFUL Operation

25English6. Press to select the desired time.• The time can be set between 0:00 and 23:50 in 10 minute intervals. • To return to the ON/OFF TIMER mo

Pagina 20 - OUTDOOR UNIT QUIET Operation

26WEEKLY TIMER OperationNOTE Notes on WEEKLY TIMER operation• Do not forget to set the clock on the remote control first.• The day of the week, ON/O

Pagina 21 - ECONO Operation

27English • A reservation made once can be copied another day of the week. The whole reservation of the selected day of the week will be copied. 1. Pr

Pagina 22 - OFF TIMER Operation

28WEEKLY TIMER Operation5. Press . • The reservation will be copied to the selected day of the week. The whole reservation of the selected day of the

Pagina 23 - ON TIMER Operation

2READ BEFORE OPERATIONSafety Precautions• Keep this manual where the operator can easily find it.• Read the precautions in this manual carefully befor

Pagina 24 - WEEKLY TIMER Operation

29English Confirming a reservation • The reservation can be confirmed.1. Press .• The day of the week and the reservation number of current day will

Pagina 25 - ON TIMER OFF TIMER

30WEEKLY TIMER Operation To delete reservations • Refer to setting mode. (page 24.) When selecting desired mode at step 4 in setting mode, select “bla

Pagina 26

31EnglishNote for Multi SystemThis system has one outdoor unit connected to multiple indoor units. Selecting the operation mode1. With the priority r

Pagina 27

32Note for Multi System OUTDOOR UNIT QUIET operation (page 19.)1. With the priority room setting present but inactive or not present.When using the OU

Pagina 28

33EnglishCARECare and Cleaning Indoor unit, outdoor unit and remote controller 1. Wipe them with dry soft cloth. Front panel 1. Open the front panel.

Pagina 29

34Care and Cleaning 1. Pull out the air filters. • Open the front panel.• Push a little upwards the tab at the center of each air filter, then pull i

Pagina 30 - Confirming a reservation

35English3-2 Titanium apatite photocatalytic air-purifying filter The titanium apatite photocatalytic air-purifying filter can be renewed by washing i

Pagina 31

36Care and CleaningCheck Before a long idle period1. Operate the FAN only for several hours on a fine day to dry out the inside.• Press and select

Pagina 32 - Note for Multi System

37EnglishTROUBLESHOOTINGTroubleshooting• Troubleshooting measures are classified into the following two types on a remedial basis. Take an appropriate

Pagina 33

38TroubleshootingThe outdoor unit emits water or steam. In HEAT operation • The frost on the outdoor unit melts into water or steam when the air cond

Pagina 34 - Care and Cleaning

3English• Do not block air inlets nor outlets. Impaired airflow may result in insufficient performance or trouble.• Do not sit or place objects on the

Pagina 35 - 2) Pull down

39EnglishOperation stopped suddenly. (OPERATION lamp is on.)• For system protection, the air conditioner may stop operating on a sudden large voltage

Pagina 36 - [Replacement]

40TroubleshootingThe ON/OFF TIMER does not operate according to the settings.• Check if the ON/OFF TIMER and the WEEKLY TIMER are set to the same time

Pagina 37

41EnglishWARNING When an abnormality (such as a burning smell) occurs, stop operation and turn the breaker off.Continued operation in an abnormal con

Pagina 38 - Troubleshooting

42Troubleshooting Fault diagnosis by remote controller In the ARC452A series, the temperature display sections on the main unit indicate corresponding

Pagina 39

43EnglishLED ON OUTDOOR UNIT PCB 3MXS, 3MKS, 4MXS, 4MKS, 5MXS, 5MKS series LED ON OUTDOOR UNIT PCB 2MXS, 2MKS seriesNOTE 1. Turn the power o

Pagina 40

44MEMO01_EN_3P266959-2A.fm Page 44 Wednesday, August 25, 2010 9:37 AM

Pagina 41

(1012)HT3P266959-2AM10B168Two-dimensional bar code is a code for manufacturing.00_CV_3P266959-2A.fm Page 2 Wednesday, September 15, 2010 9:32 AM

Pagina 42 - Disposal requirements

4Names of Parts Indoor Unit 17 1514161313457911108126201_EN_3P266959-2A.fm Page 4 Wednesday, August 25, 2010 9:37 AM

Pagina 43

5English Outdoor Unit Indoor Unit 1. Air filter2. Titanium apatite photocatalytic air-purifying filter:• These filters are attached to the inside of

Pagina 44 - ∗ REFRIGERANT SHORTAGE

6Names of Parts Remote Controller 1. Signal transmitter:• It sends signals to the indoor unit.2. Display (LCD):• It displays the current settings. (In

Pagina 45

7EnglishPreparation before Operation To set the batteries 1. Slide the front cover to take it off.2. Set 2 dry batteries AAA.LR03 (alkaline).3. Set th

Pagina 46 - 3P266959-2A

8Preparation before Operation To set the clock 1. Press .• “ ” is displayed.• “ ” and “ ” blink.2. Press to set the current day of the week.3. Pres