• Indoor Unit • Wall mounted unit • FTXN-K
1
2
• Split - Sky Air® • Indoor Unit
4
2 Specifications
Standard Accessories : Fixing screw for remote control; Quantity : 2;
Standard Accessories : Fixing screws for mounting plate; Quantity : 6;
Standard Accessories : Titanium apatite photocatalytic air purification filter; Quantity : 2;
Standard Accessories : Indoor unit fixing screws; Quantity : 2;
Standard Accessories : Mounting plate; Quantity : 1;
Standard Accessories : Remote control holder; Quantity : 1;
Standard Accessories : Wireless remote control; Quantity : 1;
Standard Accessories : Batteries; Quantity : 2;
Standard Accessories : Operation manual; Quantity : 1;
Standard Accessories : Installation manual; Quantity : 1;
Notes
(1) 220V
(2) 230V
(3) 240V
(4) SL: The silent fan level of the air flow rate setting
Sound pressure
level
Cooling High dBA 40 41 43 45
Nom. dBA33343941
Low dBA 26 27 34 36
Silent operation dBA 22 23 31 33
Heating High dBA 40 41 42 44
Nom. dBA34353840
Low dBA 28 29 33 35
Silent operation dBA 25 26 30 32
Piping
connections
Liquid OD mm - 6.35
Gas OD mm - 12.7
Drain - I.D. 14.0/O.D. 18.0
Heat insulation - Both liquid and gas pipes
Temperature control Microcomputer control
Air direction control Right, Left, Horizontal, Downward
Air filter Removable / washable / mildew proof
2-2 Electrical Specifications FTXN25KEV1B FTXN35KEV1B FTXN50KV1B FTXN60KV1B
Power supply Phase 1~
Frequency Hz 50
Voltage V 220-240
Current Nominal
running current
(RLA) - 50Hz
Cooling A
0.15 (1) 0.15 (2) 0.16 (3) 0.15 (1) 0.15 (2) 0.16 (3) 0.16 (1) 0.15 (2) 0.1 (3) 0.19 (1) 0.18 (2) 0.17 (3)
Heating A
0.15 (1) 0.15 (2) 0.16 (3) 0.15 (1) 0.15 (2) 0.16 (3) 0.17 (1) 0.16 (2) 0.16 (3) 0.21 (1) 0.20 (2) 0.19 (3)
Current - 50Hz Nominal running current A -
Current - 60Hz Nominal running current A -
Wiring connections -
50Hz
For power
supply
Remark 3 for power supply, 4 for interunit wiring (Earth
wire included)
-
2-1 Technical Specifications FTXN25KEV1B FTXN35KEV1B FTXN50KV1B FTXN60KV1B