
ELECTRICAL SPECIFICATIONS
For indoor units only: FHYP35BV1 FHYP45BV1 FHYP60BV1
CURRENT Nominal running current
cooling/heating
A See chapters RP-L7/B7, RYP-L7/B7, RYEP-L7, RZP-D
Maximum running current
cooling/heating
A See chapters RP-L7/B7, RYP-L7/B7, RYEP-L7, RZP-D
For combination indoor units + outdoor units: FHYP35BV1 FHYP45BV1 FHYP60BV1
---
CURRENT Nominal running current
cooling
A
Twin/triple/double twin application only: RP-L7/B7Maximum running current
cooling
A
Starting current
cooling
A
For combination indoor units + outdoor units: FHYP35BV1 FHYP45BV1 FHYP60BV1
---
CURRENT Nominal running current
cooling/heating
A
Twin/triple/double twin application only: RYP-L7Maximum running current
cooling/heating
A
Starting current
cooling/heating
A
For combination indoor units + outdoor units: FHYP35BV1 FHYP45BV1 FHYP60BV1
---
CURRENT Nominal running current
cooling/heating
A
Twin/triple/double twin application only: RYEP-L7Maximum running current
cooling/heating
A
Starting current
cooling/heating
A
For combination indoor units + outdoor units: FHYP45BV1 FHYP60BV1
--
CURRENT Nominal running current
cooling/heating
A
Twin application only: RZP-DMaximum running current
cooling/heating
A
Starting current
cooling/heating
A
For indoor units only: FHYP35BV1 FHYP45BV1 FHYP60BV1
POWER SUPPLY V1 V1 V1
NOMINAL DISTRIBUTION
SYSTEM VOLTAGE
Phase 1∼ 1∼ 1∼
Frequency Hz 50 50 50
Voltage V 230 230 230
NOTES
1 Nominal cooling capacities are based on: indoor temperature 27°CDB/19°CWB * outdoor temperature 35°CDB * refrigerant piping length: 7.5m *
level difference: 0m.
2 Nominal heating capacities are based on: indoor temperature: 20°CDB * outdoor temperature: 7°CDB/6°CWB * refrigerant piping length: 7.5m *
level difference 0m.
3 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
4 The sound pressure level is measured at 1.5m distance from the unit. It is a relative value, depending on the distance and acoustic
environment. For measuring conditions: please refer to item 6 of this chapter.
5 The sound power level is an absolute value indicating the ’’power’’ which a sound source generates.
6 Energy label: scale from A (most efficient) to G (less efficient).
7 Annual energy consumption: based on average use of 500 running hours per year at full load (= nominal conditions).
•
Ceiling Suspended Unit • R-407C • FHYP35-125BV1
2
Specifications
1
2
7
• Split - Sky Air • Indoor Units
Comentarios a estos manuales