21
ARCAFTXB-C
FTXB-C + RXB-C
(Note) Nominal eciency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
Eciency data FTXB + RXB *25C + 25C *35C + 35C *50C + 50C *60C + 60C
Cooling capacity Min./Nom./Max. kW 1.3/2.5/3.0 1.3/3.3/3.8 -/5.48/- -/6.23/-
Heating capacity Min./Nom./Max. kW 1.3/2.8/4.0 1.3/3.5/4.8 -/5.6/- -/6.4/-
Power input Cooling Nom. kW 0.77 0.99 1.71 1.93
Heating Nom. kW 0.69 0.93 1.49 1.77
Seasonal eciency
(according to
EN14825)
Cooling Energy label A+
Pdesign kW 2.50 3.30 5.48 6.23
SEER 6.00 6.05 5.93 6.09
Annual energy consumption
kWh 146 191 323 358
Heating (Average
climate)
Energy label A+
Pdesign kW 2.40 2.80 3.64 3.80
SCOP 4.01 4.06 4.27 4.06
Annual energy consumption
kWh 838 966 1,193 1,310
Indoor unit FTXB *25C *35C *50C *60C
Dimensions Unit HeightxWidthxDepth mm 316x870x310 386x1136x314
Weight Unit kg 8 14
Sound power level Cooling dBA 55 58 55 61
Heating dBA 55 58 55 61
Outdoor unit RXB *25C *35C *50C *60C
Dimensions Unit HeightxWidthxDepth mm 616x788x359 793x990x415
Weight Unit kg 27 29 49
Sound power level Cooling dBA 60 62 64 65
Heating dBA 60 62 64 65
Operation range Cooling Ambient
Min.~Max.
°CDB -~-
Heating Ambient
Min.~Max.
°CWB -~-
Refrigerant Type/GWP R-410A/1,975
*Note: blue cells contain preliminary data
Creating the perfect climate is what Daikin units are
all about. These wall mounted units offer pleasant
comfort for less energy use.