Options & accessories - outdoor
VRV ® OUTDOOR UNITS
VRVIII® heat recovery (high COP and small footprint combination)
VRV®-Q heat recovery
replacement VRV®
VRVIII® heat pump optimised
for heating
REYQ8P9 REYQ12P9 REMQ8P9 REMQ14-16P8
REYQ18-48P8/P9
RQ(C)EQ-P RTSYQ14P
REYQ10P8 REYQ14-16P8 REMQ10P8 REMQ12P9 REMHQ12P9
REYHQ16-24P
RTSYQ10P RTSYQ16P RTSYQ20P
Cool/heat selector
Fixing box
KJB111A
REFNET header
KHRQ23M29H KHRQ23M29H KHRQ22M29H (8)
KHRQ23M64H KHRQ23M64H KHRQ22M64H
KHRQ23M75H
REFNET joint
KHRQ23M20T KHRQ22M20T
KHRQ23M29T9 KHRQ22M29T9
KHRQ23M64T KHRQ23M64T KHRQ22M64T
KHRQ23M75T
Outdoor unit multi piping con-
nection kit
For 2 outdoor units
BHFQ23P907 BHFP26P36C
BHFQ22P1007
For 3 outdoor units
BHFQ23P1357 BHFP26P63C
For 4 outdoor units
BHFP26P84C
Central drain pan kit
KWC25C450 (2)
KWC26C280 (2) KWC26C450 (2) (10)
Digital pressure gauge kit
BHGP26A1(3)
Increase height difference between indoor & outdoor to 90m
BS Box for H/R
BSVQ100P, BSVQ160P, BSVQ250P
Central BS Box for H/R
BSV4Q100PV
Sound reduction kit for BSVQ Box
EKBSVQLNP (4)
BP Box for connection to stylish indoor units
Wind cover
Full set
KPS25C450( 5) KPS26C280 (5) KPS26C504 (5) (10)
Top/discharge
KPS25C450T (5) KPS26C280T (5)
KPS26C504T (5)
(10)
Rear/suction
KPS25C450B (5) KPS26C280B (5)
KPS26C504B (5)
(10)
Left/suction
KPS26C504L(5)
Right/suction
KPS26C504R (5)
Snowbreak hood
Kit (inlet + outlet)
KPS26C280 (9)
KPS26C504 (9)
KPS26C280X2 (9)
Air outlet
KPS26C280T (9) KPS26C504T (9)
KPS26C280TX2 (9)
Left side air inlet
KPS26C504L (9)
KPS26C504LX2 (9)
Right side air inlet
KPS26C504R (9)
KPS26C504RX2 (9)
Back side air inlet
KPS26C280B (9) KPS26C504B (9)
KPS26C280BX2 (9)
VRV ® OUTDOOR UNITS
VRV®-WIII standard series - heat recovery
RWEYQ8P RWEYQ10P RWEYQ16P RWEYQ18P RWEYQ20P RWEYQ24P RWEYQ26P RWEYQ28P RWEYQ30P
Cool/heat selector
Fixing box KJB111A
REFNET header
KHRQ23M29H
KHRQ23M64H
KHRQ23M75H
REFNET joint
KHRQ23M20T/KHRQ23M29T
KHRQ23M64T
KHRQ23M75T
Outdoor unit multi piping connection kit
For 2 outdoor units BHFP26MA56
For 3 outdoor units BHFP26MA84
Strainer kit
BWU26A15
BWU26A20
External control adapter for outdoor unit DTA104A62
BS Box for H/R
BSVQ100P8, BSVQ160P8, BSVQ250P8
Central BS Box for H/R
BSV4Q100PV, BSV6Q100PV
Notes
(1) All options are kits
(2) Central drain pan kit shall be combined based on the outdoor multi connection table
(3) Only 1 option per installation is needed
(4) Only available for standard bsvq boxes (not possible for central BSVQ). Allows to reduce operating sound of BSVQ box (requires 1 sound kit per BSVQ box)
(5) Only required for technical cooling (outdoor temperature <5°C). For more information contact your local dealer
(6) 1 Option per module is required
(7) The option should be installed inside the outdoor unit, only needed in case outdoor unit is installed above indoor
(8) Ø 25.4 Gas pipe in KHRQ22M29H is not available for DENV refnet. This is only required for the 10HP model using size uo AND with an indoor connection ratio of less than 80%
(9) Snowbreak hoods are field supply. For technical drawings and more information contact your local Daikin dealer. Snowbreak hoods are advised to be installed when regular snowfall occurs.
(10) To be combined based on the outdoor multi table.
280
Comentarios a estos manuales